- Description
- Technical Parameter
- Other Instructions
- Ordering
Name specification
1. won the EU CE certification.
2. set the level switch, the card liquid level abnormal message takes advantage of the output.
3. a motor self protection device is provided to prevent overheating and overloading.
4. release pressure release function can protect the pump and pipeline to reduce damage.
5. panel indicator can display the moving bear [YET-C1] of the oil injection machine.
6. the pressure switch can be selected freely according to the requirements of the customer (YET-C1P1).
7. has a "RES" key, which can be forced to lubricate.
The longest lubrication time of 8. is <2min, and the shortest interval time is >3min.
Scope of application
The YET type machine is suitable for the centralized lubrication system of machine tools, plastics, textile, light industry, printing and conveyor.
Appearance size diagram
Type and technical parameters:
Type and technical parameters:
|
Product No. | Single phase voltage (VAC) | Power (W) | Abnormal output connection capacity (A) | Lubrication time | Interval time | Spit out the caliber | Maximum spitting pressure (kgf/cm²) | The amount of spitting (cc/min) | Pressure switch (kgf/cm²) | Liquid level switch | Oil tank capacity (L) | Weight (kg) | |||||
YET-C1 | 111101 |
110 or 220 |
100 | Liquid level switch 0.3 | The PLC control system must be connected to the | The PLC control system must be connected to the | 4 | 7 | 200 | No | Upper power (oil conduction) | 2L (resin) | 2.6 | |||||
3L (resin) | 2.9 | |||||||||||||||||
YET-C1P1 | pressure switch 3 | 2.1↑ off | 4L (resin) | 3.2 | ||||||||||||||
4L(alufer) | 3.6 |
Wiring diagram
Hydraulic schematic diagram